Mercury removal from municipal secondary effluent with hydrous ferric oxide reactive filtration

Beutel M, , Newcombe G, Moller G. Mercury removal from municipal secondary effluent with hydrous ferric oxide reactive filtration. Water Environment Research. 2019;91:132–143.

Abstract

This study evaluated the ability of hydrous ferric oxide reactive filtration (HFO-RF) to remove mercury (Hg) from municipal secondary effluent at four study sites. Pilot HFO-RF systems (136 m3 /day) at two sites demonstrated total Hg concentration removal efficiencies of 96% (inflow/outflow mean total Hg: 43.6/1.6 ng/L) and 80% (4.2/0.8 ng/L). A lightly loaded medium-scale HFO-RF system (950 m3 /day) had a concentration removal efficiency of 53% (0.98/0.46 ng/L) and removed 0.52 mg/day of total Hg and 2.2 μg/day of methyl-Hg. A full-scale HFO-RF system (11,400 m3 / day) yielded a total Hg concentration removal efficiency of 97% (87/2.7 ng/L) and removed an estimated 0.36 kg/year of Hg. Results suggest that the quality of secondary effluent, including dissolved organic matter content, affects achievable minimum total Hg concentrations in effluent from HFO-RF systems. Low HFO-RF effluent concentrations (<1 ng/L) can be expected when treating secondary effluent from suspended-growth biological treatment systems. 
Last updated on 07/20/2022